GW 3P/3P provides up to 1.0 output power factor, providing higher performance and efficiency for critical applications. This powerful online series integrates true double conversion design, DSP technology and active input power factor correction design to ensure better output voltage, power quality and performance at all times, LCD display provides real-time UPS status, enhanced flexibility to meet the growing power needs of IT and network environments.
True double conversion online uninterruptible power supply system
DSP technology ensures high performance
Output power factor
Active power factor correction
50/60hz frequency conversion mode
ECO energy-saving operation function
Emergency power-off function (EPO)
Optional parallel function
Intelligent charging design to optimize battery performance
Built-in maintenance bypass switch
Adjustable number of battery cells
Information industry
IT industry
Financial industry
Aerospace
Industry
Computer
Communication
Data network center
Model | Power | Size (Width * depth * height) | Weight (kg) |
GW33-10KL | 10KVA/8KW | 405*656*817mm | 120 |
GW33-15KL | 15KVA/12KW | 405*656*817mm | 145 |
GW33-20KL | 20KVA/16KW | 405*656*817mm | 193 |
GW33-30KL | 30KVA/24KW | 405*656*941mm | 225 |
GW33-40KL | 40KVA/32KW | 432*821*1159mm | 278 |
GW33-60KL | 60KVA/48KW | 432*821*1159mm | 365 |
GW33-80KL | 80KVA/64KW | 554*975*1286mm | 471 |
GW33-100KL | 100KVA/80KW | 554*975*1286mm | 573 |
GW33-120KL | 120KVA/96KW | 635*975*1326mm | 650 |
GW33-160KL | 160KVA/128KW | 705*1051*1646mm | 760 |
GW33-200KL | 200KVA/160KW | 705*1051*1646mm | 790 |
*Current specifications and dimensions are subject to change without prior notice.
Phase | 3Phase in/3Phase out | |||||||||||
Input | ||||||||||||
Rated voltage | 3x380 / 400 VAC (3Ph+N) | |||||||||||
Acceptable voltage range | 165VAC~280VAC(Ph-N);285VAC~485VAC(Ph-Ph) | |||||||||||
Frequency | 50-60Hz±10% | |||||||||||
Inverter | ||||||||||||
Admissible | Power Factor | 0.6-1 | ||||||||||
Admissible | Crest factor | 3:01 | ||||||||||
Admissible | overload | 110%~150%10min~60sec | ||||||||||
Limiting | High overload, short circuit: effective value voltage limit; peak factor current: peak voltage limit | |||||||||||
Dynamic recovery time | 3 cycles | |||||||||||
Frequency | 50/60Hz | |||||||||||
Unbalanced output voltage/100% unbalanced load | <1% | |||||||||||
Maximum sync speed | ±1Hz/s | |||||||||||
Rated voltage | 3x380/400/415VAC(3Ph+N) | |||||||||||
Phase | 120°±1% (balanced load) | |||||||||||
Accuracy | Static: ±1%, Temporary: ±5% | |||||||||||
Total harmonic distortion (THDV) | <2% linear load | |||||||||||
Waveform | pure sine wave | |||||||||||
Static bypass | ||||||||||||
Activation criteria | microprocessor controlled | |||||||||||
Allow overload | 0~150% continuous working; 150-180%60min; >180%5min | |||||||||||
Frequency | 50/60Hz±10% | |||||||||||
Transfer again | Automatically after the alarm is cleared | |||||||||||
Transfer time | Zero | |||||||||||
Transfer to bypass | Immediately, for over 160% overload | |||||||||||
Type | solid state | |||||||||||
Voltage | 176VAC-264VAC(Ph-N); 304VAC-456VAC(Ph-Ph) | |||||||||||
Bypass maintenance | ||||||||||||
Frequency | 50/60Hz | |||||||||||
Overall efficiency | battery mode | 90% | 91% | 92% | 92% | 93% | ||||||
Overall efficiency | line mode | 89% | 90% | 91% | 91% | 92% | ||||||
Type | uninterrupted | |||||||||||
Voltage | 3x400VAC(3Ph+N) | |||||||||||
Batteries and chargers | ||||||||||||
Charging method | CC/CV | |||||||||||
Charging voltage | 432VDC | |||||||||||
Rated battery voltage | 384VDC | |||||||||||
Accuracy | ±1% | |||||||||||
Battery type and quantity | 12VDCX32PCS | |||||||||||
recharging current | 10A |