GE33 series industrial online UPS adopts advanced full DSP digital control technology to achieve the leap from analog to digital control. For power outages that often occur in the power grid, the mains voltage is too high or too low, instantaneous voltage drops or amplitude oscillations, high voltage pulses, voltage fluctuations, surge voltages, harmonic distortion, clutter interference, frequency fluctuations, etc., even in the face of It can operate stably in harsh environments and provide high-quality, highly reliable power protection for all electrical equipment and data processing processes with important missions to ensure the safe operation of electrical equipment, improve its productivity and availability, and extend its service life.
True double-conversion online uninterruptible power supply system
DSP technology ensures high performance
Built-in isolation transformer design
Industrial-grade design can be used in various harsh conditions
Intelligent battery management to extend battery life
Independent air duct Designed to operate continuously in harsh environments
Adjustable battery cell number and dual input options
Can operate up to 4 units in parallel
Diverse communication interfaces 10. Optional 7 touch color LCD screens
Supports input errors Phase rectification and no N line input
Precision instruments
Medical equipment
Data center
Education
Telecommunications
Communications
Finance
Transportation
Model | Power | Size (Width * depth * height) | Weight (kg) |
GE33-10KL-6M | 10KVA/8KW | 300*600*810mm | 110kg |
GE33-15KL-6M | 15KVA/12KW | 300*600*810mm | 130kg |
GE33-20KL-6M | 20KVA/16KW | 300*600*810mm | 160kg |
GE33-30KL-6M | 30KVA/24KW | 400*750*1010mm | 200kg |
GE33-40KL-6M | 40KVA/32KW | 400*750*1010mm | 225kg |
GE33-50KL-6M | 50KVA/40KW | 720*600*1500mm | 260kg |
GE33-60KL-6M | 60KVA/48KW | 720*600*1500mm | 277kg |
GE33-80KL-6M | 80KVA/64KW | 720*600*1500mm | 405kg |
GE33-100KL-6M | 100KVA/80KW | 700*800*1500mm | 510kg |
GE33-120KL-6M | 120KVA/96KW | 700*800*1500mm | 580kg |
GE33-160KL-6M | 150KVA/128KW | 700*800*1700mm | 780kg |
GE33-200KL-6M | 200KVA/160KW | 700*800*1700mm | 850kg |
GE33-300KL-6M | 300KVA/240KW | 700*800*1700mm | 995kg |
GE33-400KL-6M | 400KVA/320KW | 1200*1000*1800mm | 1435kg |
GE33-500KL-6M | 500KVA/400KW | 1400*1000*1900mm | 1600kg |
GE33-600KL-6M | 600KVA/480KW | 1400*1000*1900mm | 1770kg |
GE33-800KL-6M | 800KVA/640KW | 2400*1200*1910mm | 2500kg |
GE33-1000KL-6M | 1000KVA/80KW | 2400*1200*1910mm | 2900kg |
Input | ||||||||||||||
Rated voltage | 3X380/400/415VAC(3Ph+N) | |||||||||||||
Acceptable voltage range | ±25% | |||||||||||||
Frequency | 50/60HZ | |||||||||||||
Output | ||||||||||||||
Voltage regulation | ±1% | |||||||||||||
The output voltage | 380/400/415VAC | |||||||||||||
Frequency Range | 50/60Hz | |||||||||||||
Transfer time | AC mode is DC mode | 0 | ||||||||||||
Transfer time | Waveform (battery mode) | sine wave | ||||||||||||
Transfer time | Inverter to bypass | 0 | ||||||||||||
Efficiency | battery mode | 92% | ||||||||||||
Efficiency | line mode | 83% | ||||||||||||
Frequency Range | 45-64Hz | |||||||||||||
Current peak ratio | 3;1 | |||||||||||||
Harmonic distortion | <3% | |||||||||||||
Inverter | ||||||||||||||
Admissible | Power Factor | 0.6-1 | ||||||||||||
Crest factor | 3;1 | |||||||||||||
overload | 110~150% | |||||||||||||
Limiting | Overload, short circuit, overvoltage | |||||||||||||
Dynamic recovery time | 3 cycles at 90% | |||||||||||||
Frequency | 50/60HZ | |||||||||||||
Unbalanced output voltage | <15 | |||||||||||||
Maximum sync speed | ±1% | |||||||||||||
Rated voltage | 3x 380/400/415VAC | |||||||||||||
Phase | 120°±1% | |||||||||||||
Accurate | Still 1% | |||||||||||||
Total harmonic distortion | <2% | |||||||||||||
Waveform | sine wave | |||||||||||||
Static bypass | ||||||||||||||
Activation criteria | microprocessor control | |||||||||||||
Allow overload | 0%-150% continuous work | |||||||||||||
Frequency | 50/60Hz | |||||||||||||
Transfer again | Automatically after the alarm is cleared | |||||||||||||
Transfer time | 0 | |||||||||||||
Transfer to bypass | Immediately for overloads exceeding 160% | |||||||||||||
Type | solid state | |||||||||||||
Voltage | 176-456VAC | |||||||||||||
Bypass maintenance | ||||||||||||||
Frequency | 50/60Hz | |||||||||||||
Overall efficiency | battery mode | 10K, 15K efficiency≥90%; 20K, 30K efficiency≥91%; 40K-60K efficiency≥92%; efficiency above 80K≥93% | ||||||||||||
line mode | 10K, 15K efficiency≥89%; 20K, 30K efficiency≥91%; 40K-60K efficiency≥91%; efficiency above 80K≥92% | |||||||||||||
Type | uninterrupted | |||||||||||||
Voltage | 3X400VAC(3Ph+N) | |||||||||||||
Batteries and chargers | ||||||||||||||
Charging method | CC/CV | |||||||||||||
Charging voltage | 432VDC | |||||||||||||
Rated battery voltage | 384VDC | |||||||||||||
Accuracy | 1% | |||||||||||||
Battery type and quantity | 12VDCX32pcs | |||||||||||||
Recharging current | Default 10; Maximum 40; 5A@full load |